100+ rich categories with a wide range of certifications
hot keywords:

RE-2X(St)Y-PiMF XLPE insulation PVC sheath

RE-2X(St)Y-PiMF XLPE insulation PVC sheath

EN 50288-7 standard instrument cable is used for the transmission of analog and digital signals in instrument control systems. According to IEC79-14 classification, it can be used in Group I Zone 1 and Zone 2 environments. It cannot be directly connected to low-impedance power supplies, such as public power supply stations. It is recommended for indoor and outdoor installations, brackets, trays, pipelines, dry and wet environments. It is not recommended for direct burial. It is recommended for fire protection measures for life and important property materials.

inquiry
  • Product details
Product introduction
  • 01 Product application EN 50288-7 standard instrument cable is used for the transmission of analog and digital signals in instrument control systems. According to IEC79-14 classification, it can be used in Group I Zone 1 and Zone 2 environments. It cannot be directly connected to low-impedance power supplies, such as public power supply stations. It is recommended for indoor and outdoor installations, brackets, trays, pipelines, dry and wet environments. It is not recommended for direct burial. It is recommended for fire protection measures for life and important property materials.
  • 02 Product characteristics · Flame retardant in accordance with EN 60332-1-2; IEC 60332-1-2;  BS EN 60332-1-2;
    · Customization is acceptable for products with special structures, other sizes, cores and colors of sheathing.
  • 03 Technical Certification· Comply with ROHS standards
    · Comply with the 2014/35/EU- Directive (" Low Voltage Directive ")CE.
Product structure

Conductor material: bare copper wire

Conductor type :IEC 60228 Class 1 solid annealed copper conductor or Class 2 multi-strand plain copper conductor

Core wire insulation :XLPE

Core cable identification: black, white, and red. The cables in the three-wire group are continuously identified by numbers (1,2,,,,) on the white core.
                                        Black/white, pairs of cables are continuously identified by numbers (1,2,,,,) on the white cor

Pairs :2 or 3 insulated wire cores are twisted together to form pairs.

Stranding: three-wire group or pair group to lay the synthetic layer.

Subshield: Aluminum foil/polyester tape with solid tinned copper flow wire wrapped around the outer layer of the single wire group

Total shielding: Aluminum strip/polyester strip shield with 0.5mm² tinned copper drain line.

Outer sheath: thermoplastic PVC composite

Jacket color: black RAL 9005 or blue

Rated voltage :300/500V

Test voltage: 2.0 kV

Conductor resistance: According to IEC 60228 standard

Small bending radius fixed: 7.5 x d

Small bending radius movement :15 x d

Temperature rating fixed :-15°C/+90°C

Temperature rating shift :-5°C/+90°C

Flame retardant rating: IEC 60332-1-2

Standard :BS EN 50288-7 standard

Product identification :Aein bei ke SHANGHAI AEIN WIRE & CABLE CO.LTD Model Specification Voltage CE meter standard

Recommended news